Fire Inspection Checklist

A fire-safety inspection of a building or workplace covering equipment, exits and hazards.

Published July 5, 2026

Download PDF

Fire Extinguishers and Equipment

  • Confirm extinguishers are present, charged and within their service date.
  • Check the pressure gauge, pin and tamper seal on each unit.
    The needle should sit in the green zone; missing pins or broken tamper seals require servicing.
  • Verify extinguishers are mounted, signed and unobstructed.
    Note the inspection tag date for each extinguisher.
  • Confirm fire blankets and hose reels, where fitted, are accessible.
  • Check that monthly and annual inspection records are current.

Exits, Doors and Lighting

  • Walk every exit route and confirm it is clear and unobstructed.
  • Check exit doors open freely and are not locked or blocked.
  • Confirm fire doors close and latch and are not propped open.
    Wedging fire doors open allows smoke and flames to spread rapidly along corridors and escape routes.
  • Verify exit and directional signs are visible and illuminated.
    Report any propped fire door or failed exit sign immediately.
  • Test emergency and backup lighting along escape routes.
  • Confirm stairwells are clear and self-closing doors function.

Alarms and Detection Systems

  • Confirm smoke and heat detectors are in place and not painted over.
    Paint or heavy dust over sensor vents blinds the device and delays critical early warning.
  • Verify the fire alarm panel shows no faults and is monitored.
  • Test that alarm signals are audible and visible throughout.
  • Check manual call points are accessible and unobstructed.
  • Confirm the last alarm service and test dates are recorded.

Sprinklers and Suppression

  • Confirm sprinkler heads are unobstructed and undamaged.
  • Verify at least the required clearance below each sprinkler head.
    Keep storage well below sprinkler heads to maintain coverage.
  • Check control valves are open, accessible and supervised.
  • Confirm kitchen or specialty suppression systems are serviced.
  • Verify the last sprinkler inspection and service dates are recorded.

Hazards and Storage

  • Check electrical panels are accessible with required clearance.
    Keep a clear, unobstructed zone around panels to ensure quick access during an emergency shutdown.
  • Inspect wiring, cords and sockets for damage or overloading.
  • Confirm flammable liquids are stored in approved cabinets.
  • Verify combustible waste and materials are kept away from ignition sources.
  • Check that aisles, exits and equipment access remain clear.

Documentation and Follow-Up

  • Record the date, inspector and areas covered.
  • Document each deficiency with a clear location and description.
    Include photos and specific room numbers to help maintenance teams locate and fix issues quickly.
  • Assign corrective actions with owners and target dates.
  • Track deficiencies to closure and verify completed repairs.
  • Confirm inspection records are retained and accessible.
    This is general guidance only and does not replace OSHA regulations, local fire codes, formal training or inspection by a qualified person or the authority having jurisdiction; confirm requirements for your building.

Inspector sign-off

  • Result (Compliant / Corrective action needed): ____
  • Defects reported to (supervisor): ________________
  • Signature: ________________

0 / 34 done

Walk through a building to verify fire-safety compliance using a fire inspection checklist covering extinguishers, exits, alarms, sprinklers, electrical hazards, and storage. It documents the physical condition of fire safety provisions at a point in time.

Where a fire prevention program sets the rules, an inspection verifies that the building actually meets them. A methodical walk finds the blocked sprinkler head, the dead emergency light or the propped fire door before an inspector or a fire does.

This checklist is written for facility managers, safety officers and fire wardens who need a concrete, building-focused inspection list with a dated record of findings. It supports, but does not replace, inspection by the authority having jurisdiction.

Keep a printable copy on your clipboard or the PDF on a tablet, walk the building on a set schedule, and log the date, the inspector and every deficiency with its corrective action.

Regulatory basis: OSHA 29 CFR 1910.157(e)(2) requires portable fire extinguishers to be visually inspected monthly, and 1910.157(e)(3) requires an annual maintenance check with the date recorded. Exit routes must be kept free and unobstructed (29 CFR 1910.37). Local fire codes and NFPA 10 often add requirements. Rules change and vary by jurisdiction — confirm against the current regulation text, your employer's procedures and the manufacturer's manual.

FAQ

How is a fire inspection different from a fire safety program?

A fire safety program sets prevention rules, training and procedures, while a fire inspection is a point-in-time walkthrough that verifies the building physically meets those requirements and documents any deficiencies for correction.

How often should a building fire inspection be done?

Conduct internal inspections at least monthly for extinguishers and quarterly for a broader walk, with annual professional servicing of alarms, sprinklers and suppression systems. Your local fire code may require specific intervals.

What are common fire inspection failures?

Frequent findings include blocked or locked exits, obstructed extinguishers or sprinkler heads, expired equipment, failed emergency lighting, propped fire doors and improperly stored combustibles or flammable liquids.

Who can carry out a fire inspection?

Trained facility staff or safety officers can run routine internal inspections, while the authority having jurisdiction conducts official inspections. Alarm and sprinkler systems generally require servicing by qualified contractors.

Does this checklist replace an official inspection?

No. It is general guidance and does not replace OSHA regulations, local fire codes, formal training, your employer's fire program, or inspection by a qualified person or the authority having jurisdiction. Always confirm the rules for your building.

How often must fire extinguishers be checked?

Under OSHA 29 CFR 1910.157, portable extinguishers get a visual inspection every month and a maintenance check every year; the annual check date must be recorded and kept.

What should you do immediately if a fire hazard or defect is found during an inspection?

If an immediate hazard like a blocked exit route or a non-functioning fire door is found, resolve it on the spot if it is safe to do so. For issues requiring maintenance, record the exact location and description, notify the property manager or safety officer promptly, and secure any hazardous area. Set a firm target date for completion and conduct a follow-up walkthrough.

What extra precautions are needed when inspecting areas with battery charging or specialized storage?

Battery charging areas, such as those for power tools or electric mobility devices, require dedicated, well-ventilated spaces away from combustible goods. Check that chargers sit on non-combustible surfaces, look for heat damage or frayed cables, avoid daisy-chained extension cords, and verify an appropriate fire extinguisher is immediately accessible.

Built from public guidance and kept up to date — how we write our checklists. Spotted a mistake? Tell us.